SINBAD ABSTRACT NEA-1517/80
RFNC Photon Spectra from H2O, SiO2 and NaCl
1. Name of Experiment: ------------------ Measurement of Photon Leakage Spectra from Spherical and Hemispherical Samples of H2O, SiO2 and NaCl compounds with a Central 14-MeV Neutron Source. 2. Purpose and Phenomena Tested: ---------------------------- Measurement of spectra and leakages of photons from thick spherical and hemispherical samples of widespread earth’s crust elements irradiated with a Central 14-MeV Neutron Source for validation of existing nuclear data on gamma- production of these elements. 3. Description of the Source and Experimental Configuration: -------------------------------------------------------- For these measurements has been using the same equipment as for paper [1]. An installation NG-200 (200-KeV deuteron accelerator with the current of separated D+ ion beam of up to 1 mA) was used as 14-MeV neutron source. The target was placed in the center of spherical samples of inside diameter 100 mm and outside diameter 200 mm. 4. Measurement System and Uncertainties: ------------------------------------ The measurements were performed using a scintillation detector having a stilbene crystal with dimensions of 60x60 mm. Gamma-neutron separation was done using the scintillation pulse shape. Direct 14-MeV neutrons from the target that were not scattered by the sample were delayed by a steel rod of diameter 30 mm and length 400 mm, placed in the immediate vicinity of the sample. Between the source and the detector, a concrete 1.5-m thick wall with a collimator was situated. To reduce the background of scattered photons and cosmic rays the detector was placed in a shield of 50-mm thick lead bricks. In addition, to reduce the background from secondary gamma-rays falling on the detector due to interaction of neutrons with materials surrounding the detector, a polyethylene cylinder of diameter 100 mm and length L=200 mm was placed into the collimator. The cylinder substantially (approximately by 10 times) absorbed neutrons and not very heavily (2-3 times) absorbed gamma-rays. The 14-MeV neutron flux was measured with an all-wave detector pre-calibrated in absolute measurements of the neutron flux of the installation. These absolute measurements were conducted using the activation method and the reaction Al-27(n,alpha)Na-24. When replacing the samples, the indications of the all-wave detector were adjusted according to the flux amplification/attenuation coefficient of the samples used. The coefficients were measured experimentally as a relationship of count rate of the all-wave detector with and without the sample. 4.1. Measuring equipment and processing of experimental spectra. The photon spectrum measurements were conducted using a scintillation detector having a stilbene crystal with dimensions of 60x60 mm. Measured energy range is 0.3 - 8.0 MeV. Energy resolution for lines Co-60 (1.17 and 1.33 MeV) was about 10%. At energies higher than 3 MeV it was 6-7% and at energies less than 0.5 MeV it was 15-20%. Processing of experimental electron-recoil spectra for transferring them into the photon spectra, was conducted using the method of “generalized differentiation”. The results of measurements are presented in Table 2. 4.2. Measurement uncertainty. The measurement uncertainty is a sum of the following components: Statistical uncertainty Delta1=+-5 %. Uncertainty in the detector efficiency. The detector efficiency was determined by measuring the spectra of standard preparations of Na-22, Cs-137, Co-60, Na-24. Within the energy range 0.5 - 3.0 MeV this uncertainty is estimated as ±5 %. Within the range 3 - 8 MeV the efficiency uncertainty may reach Delta2=7-8% due to the absence of standard preparations reference specimens with such energy. Uncertainty in mathematical processing of the experimental spectra is Delta3=+-7%. Sum of the above mentioned uncertainties is 12%. Possible uncertainty of the both sphere radii is ±1 mm and possible uncertainty of target unit dimensions is ±0.1 mm. 5. Description of Results and Analysis; Comparison with Calculations: ----------------------------------- The MCNP input used in the analysis is provided in mcnp5.inp. The d-t source is described as monochrome (14 MeV) and isotropic. According to the author of the experiment these simplifications could effect the neutron measurements, but are insignificant for photon measurements. Using the MCNP input and the explanation in the text more detailed source description can be prepared. Figure 2 provides some details of the target unit allowing an explicit modeling of the (d-t) reaction, if some users may wish to do it. Arrangement of the layers at the end of target tube in the direction of the d beam is as follows: - Zr foil saturated with t (0.05 mm thick), placed in the center of the spheres - Cu (3 mm thick) - water used as coolant (1.5 mm) - Cu (0.5 mm) The uncertainty of the above values is about 0.1 mm. The gap between Fe and Cu (mats. 2 and 3 in Fig. 2) on the side surface is also filled with water. Figures 5-9 show that the photon spectra are very various and individual for each compound. The spectra of the hemispheres repeat the structure of the sphere’s. This shows the high relative accuracy of the measurements performed. In some cases the spectra calculated using the code MCNP and library ENDF/B-VI rel.6 differ greatly from the experiments and fall far outside the limits of experimental uncertainty. * H2O. All the experimental gamma-peaks are visible in the calculation spectra too. They agree on the height. The 2.25 MeV peak is produced on hydrogen (H) and other peaks are on oxygen (O). The main peaks 3.72, 613 and 7.1 MeV and some small peaks are identified in the measurements and the calculations. The annihilation peak 0.51 MeV is present in all the experiments and calculations. * SiO2. In the range < 1.5 MeV, as for water one needs taking into account the neutron generator target construction and the container. Elsewhere the calculated gamma leakage is underestimated by two times and the 0.85 MeV peak is absent. The main peaks are 1.78 MeV on Si and 3.72, 613 and 7.1 MeV on O. Two close peaks 2.75 MeV on O and 2.82 MeV on Si are joined in one. All the experimental gamma-peaks are visible in the calculated spectra but many of them are underestimated. It requires an essential increasing of the gamma-production on the Si nuclei. * NaCl. All the main experimental gamma-peaks (0.44, 1.28, 1.65, 2.20 and 3.50 MeV) are visible in the calculated spectra too but a lot of them are underestimated. It requires an essential increasing of the gamma-production on the Na and Cl nuclei. There are significant discrepancies in gamma-production of the calculations and the experiments for these elements. The accepted nuclear data should be appropriately updated. Any extrapolation of the leakage photon data in uninvestigated neutron energy intervals will be unreliable. Experiments on gamma-production for neutron energy range 5 - 10 MeV are necessary. 6. Special Features: ---------------- Method of generalized differentiation with semi-empirically determined coefficients in order to transfer apparatus electron-recoil spectra into energy spectra. 7. Author/Organizer ---------------- Experiment and Analysis: A.I. Saukov, V.D. Lyutov, E.N. Lipilina Institution: RFNC-VNIITF Compiler of data for SINBAD: A.I. Saukov, V.D. Lyutov, E.N. Lipilina Institution: RFNC-VNIITF Reviewer of compiled data: I. Kodeli OECD/NEA, 12 bd des Iles, 92130 Issy les Moulineaux, France 8. Availability: ------------ Unrestricted 9. References: ---------- [1] A.I. Saukov, V.D. Lyutov, E.N. Lipilina, "Photon Leakage Spectra from Al, Ti, Fe, Cu, Zr, Pb, U-238 Spheres", SINBAD Database, OECD NEA Data Bank, France, Paris, identifier NEA-1517/72, 2006. 10. Data and Format: --------------- DETAILED FILE DESCRIPTIONS -------------------------- Filename Size[bytes] Content --------------- ----------- ------------- 1 rfnc_g2-a.htm 11.139 This information file 2 rfnc_g2-e.htm 12.450 Description of experiment 3 mcnp5.inp 2.624 Input data for the MCNP5 calculation 4 Fig1geo.jpg 74.898 Fig. 1. Geometry of experiment 5 Fig2mishen.jpg 85.485 Fig. 2. Design of the target unit 6 Fig3na22.jpg 45.163 Fig. 3. Gamma-spectrum of Na-22 specimen 7 Fig4na24.jpg 40.857 Fig. 4. Gamma-spectrum of Na-24 specimen 8 Fig5h2osph.jpg 224.529 Fig. 5. Photon spectra from H2O sphere (calculated and experimental) 9 Fig6sio2sph.jpg 228.391 Fig. 6. Photon spectra from SiO2 sphere (-"-) 10 Fig7sio2hsph.jpg 237.976 Fig. 7. Photon spectra from SiO2 hemisphere (-"-) 11 Fig8naclsph.jpg 232.400 Fig. 8. Photon spectra from NaCl sphere (-"-) 12 Fig9naclhsph.jpg 212.783 Fig. 9. Photon spectra from NaCl hemisphere (-"-) 13 tab1samples.txt 158 Table 1. Parameters of samples used 14 tab2res.txt 4.545 Table 2. Results of measurements 15 tab2res.xls 25.600 Table 2. Results of measurements (XLS format) SINBAD Benchmark Generation Date: 5/2007 SINBAD Benchmark Last Update: 5/2007